Engaging in Generator More Than 15 Years
Blog
  • How is the quality of Weichai Generator? Aug 30, 2024
    How is the quality of Weichai Generator?   Let me start with the conclusion: The quality of Weichai generators is excellent. Weichai is a well-known Chinese brand with a strong reputation in the engine and power generation industries, including marine applications. Weichai Profile   Weichai Power is one of the earliest Chinese companies to develop and produce engines for generator sets, boasting over 60 years of production history. The company specializes in both land and marine generator sets, offering a wide range of diesel and gas-powered solutions. Notably, Weichai Silent Generators are recognized as a national production site for small and medium-sized generator sets and serve as the Vice Chairman unit of the Internal Combustion Power Generation Equipment Branch of the China Electrical Equipment Industry Association.   Weichai Power is committed to delivering comprehensive, safe, and efficient power solutions, backed by advanced technology, a rigorous management sys...
  • Key Signs to Watch for in Diesel Generator Performance Aug 28, 2024
    Diesel generator sets are indispensable and important equipment in industrial production, commercial operations and family life, which provide us with a stable power supply. However, like other mechanical equipment, diesel generator sets may also have various problems. If the signs of these problems can be discovered in time and appropriate measures can be taken, the failure can be avoided and the service life of the generator set can be extended. So, what are the common signs when there is a problem with the generator set? 1.Abnormal Noise: A normally operating generator set should be relatively quiet. If you hear abnormal noise from the generator set, such as knocking, friction, roaring, etc., this may mean that there are loose parts, wear or other faults inside the unit. Understanding and Fixing Abnormal Noise in Generator Sets: Causes and Solutions 2.Over Temperature: The generator set generates heat during operation, but if the temperature of the unit is too high, even hot, this m...
  • Understanding and Fixing Abnormal Frequency in Generator Sets: Causes and Repair Solutions Aug 28, 2024
    Section 1: Common Causes of Abnormal Frequency in Generator Sets   1. Engine Speed Issues   Explanation: Generator frequency is directly related to the engine’s speed (RPM). If the engine speed fluctuates, it will cause frequency variations. Solution: Check the engine’s governor and fuel system to ensure the engine maintains a stable speed. Adjust or repair the governor if necessary.   2. Faulty or Malfunctioning Governor   Explanation: The governor controls the engine speed to maintain a steady frequency. A malfunctioning governor can cause the generator to run at incorrect speeds, leading to abnormal frequency. Solution: Inspect the governor system for wear or damage. Calibrate, repair, or replace the governor as required.   3. Load Imbalance   Explanation: An imbalance in the load distribution across the generator’s phases can cause fluctuations in frequency. Solution: Ensure the load is evenly distributed across all phases. Use a load...
  • Generator Set Over-Temperature: Causes and Repair Solutions Aug 28, 2024
    Section 1: Common Causes of Over-Temperature in Generator Sets 1. Insufficient Coolant Levels   Explanation: Coolant helps dissipate heat from the engine. Low coolant levels can cause the engine to overheat. Solution: Regularly check and maintain the coolant levels. Refill with the appropriate coolant mixture if necessary. 2. Clogged or Dirty Radiator   Explanation: A clogged or dirty radiator cannot effectively cool the engine, leading to overheating. Solution: Clean the radiator regularly to remove dirt, debris, and blockages. If the radiator is damaged, it may need to be replaced. 3. Faulty Thermostat   Explanation: The thermostat regulates the flow of coolant through the engine. A malfunctioning thermostat can restrict coolant flow, causing the engine to overheat. Solution: Test the thermostat for proper operation and replace it if it is not functioning correctly. 4. Inadequate Airflow   Explanation: Insufficient airflow to the radiator or engine compartment can...
  • Understanding and Fixing Abnormal Noise in Generator Sets: Causes and Solutions Aug 28, 2024
    Section 1: Common Causes of Abnormal Noise in Generator Sets - 1. Loose or Worn Components   - Explanation: Vibrations can cause bolts, nuts, and other components to loosen over time. Worn parts can also generate unusual sounds.   - Noise Characteristics: Rattling or clanking sounds.   - Solution: Regularly inspect and tighten any loose parts. Replace worn components.   - 2. Misaligned or Damaged Bearings   - Explanation: Bearings that are worn out, misaligned, or lack lubrication can produce grinding or screeching noises.   - Noise Characteristics: Grinding, whining, or screeching sounds.   - Solution: Inspect bearings for wear or misalignment. Lubricate or replace them as needed.   - 3. Exhaust System Issues   - Explanation: A damaged or loose exhaust system can cause loud, unusual noises, often mistaken for engine issues.   - Noise Characteristics: Loud, booming, or hissing sounds.   - Solution: Check the exhaust system for leak...
  • ISO Standards for Generator Sets Aug 27, 2024
      ISO Standards for Generator Sets: ISO 8528: Scope: Defines applications, ratings, performance, and characteristics of generator set components like engines, alternators, controls, and switchgear. Functional Tests: Covers methods for functional and acceptance tests, including vibration and sound measurements. Load Factor: Specifies that the average power output of generator sets over 24 hours should be 70% of the nameplate kW rating,  ISO 3046: Scope: Focuses on engine characteristics, including power ratings, fuel consumption, and vibration. Conformance: Typically noted on a generator set’s specification sheet. ISO 9001: Scope: Establishes the requirements for a quality management system (QMS). Certification: All MTU manufacturing facilities are ISO 9001:2015 certified. ISO 14001: Scope: Defines environmental management practices for manufacturing. Certification: All MTU facilities are ISO 14001 certified. ISO 17025: Scope: Pertains to the testing and calibration of i...
  • How to Choose the Fuel for Diesel Generator Sets? Aug 26, 2024
    How to choose the fuel for diesel generator sets? Most users may only know that they need to use diesel, but do you know what kind of diesel to use? The main fuel for diesel engines is diesel. Diesel is made from petroleum after refining and processing. Its main characteristics are low autoignition point, high density, strong stability, safe use, and low cost, but its volatility is poor. When the ambient temperature is low, the diesel engine is difficult to start. Light diesel is used for high-speed diesel engines, and heavy diesel is used for medium and low-speed diesel engines. The properties of diesel have a great influence on the power, economy and reliability of diesel engines.   The following are suggestions for selection   The performance, specifications and selection of diesel The lowest temperature at which diesel spontaneously ignites without external ignition is called the autoignition temperature of diesel. The autoignition performance of diesel is expressed by th...
  • Cummins Generator Manual Aug 23, 2024
    Cummins Generator Manual Download   We have maintained a strong partnership with Cummins for several decades, enabling us to provide a comprehensive range of their high-quality products. Our offerings include:   Cummins Generator Sets: Available in various capacities, these generators are built to deliver consistent power and efficiency, making them ideal for both standby and continuous power needs. include Cummins industrial generator, cummins marine generator   Cummins Spare Parts: We supply a full range of genuine Cummins spare parts, ensuring your engines and generators operate at peak performance with minimal downtime.   Cummins Maintenance Kits: Tailored to keep your equipment in top condition, these kits include everything needed for regular maintenance and preventive care.   This extensive collaboration with Cummins allows us to offer unmatched expertise and support for all your power generation needs.   reach out to us below https://wa.me/message/...
  • How to Choose an Emergency Diesel Generator Set? Aug 21, 2024
    Hosem generator sets are primarily used in critical environments to quickly restore power and extend supply time during a power outage or emergency. Such power loads are referred to as primary loads. For systems like communication equipment, instruments, and computer systems that have strict requirements for uninterrupted power, in addition to a generator set, a backup battery or UPS should also be installed.   The operation of a Hosem generator set has two key characteristics:    1. Emergency Use: The continuous operation time is usually short, generally needing to run for only a few hours (≤12h). Emergency Generator For Commercial Building Standby Power Generation 2. Standby Use: The emergency generator set remains in a standby mode most of the time, only starting up when the main power source fails. Once the main power source is restored, the generator set will automatically switch off. Standby Power Generators | Cummins Powered   Determining the Capacity of D...
1 2 3 4 ... 8
Whatever your needs, our equipment will ensure your business is always on.
Get a quote

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

skype

whatsapp