Tel : +86-591-86397381
Email : sale@hosempower.com
Skype : +86-13205904365
Perkins as one of the most popular engine manufactor, has a widespread and well-established global service network. This network ensures reliable access to maintenance, service, and spare parts, enhancing the generator's overall reliability and ease of maintenance.
There is no doubt Perkins is the one of the best choices for your power generating, Contact us today for more information
Item no.:
A-P33Payment:
TT/LCPrice:
$7000Product origin:
ChinaColor:
GrayProduct weight:
950Lead Time:
30-35 days
Our Perkins 30kVA diesel generator embodies the pinnacle of reliability, offering steadfast performance backed by the renowned Perkins engine. Engineered for efficiency and durability, this generator ensures uninterrupted power supply across various applications. The Perkins 30kVA diesel generator embodies the pinnacle of reliability, offering steadfast performance backed by the renowned Perkins engine. Engineered for efficiency and durability, this generator ensures uninterrupted power supply across various applications.
1. Engine: Equipped with a robust Original Perkins engine, complete with heavy-duty air, oil, and fuel filters, along with a fuel and water separator for enhanced performance and longevity.
2. Alternators: Standard Koten brand brushless AC alternators, with optional upgrades to reputed brands like Stamford, Leroy Somer, Marathon, or Meccalte.
3. Cooling System: Utilizes a large-size radiator to maintain optimal operating temperatures for the engine.
4. Vibration Control: Features heavy-duty anti-vibration pads to reduce operational vibrations, ensuring stability and longevity.
5. Base Frame: Built on a heavy-duty steel base frame with an 8-hour continuous working fuel tank for extended operation.
6. Canopy: Constructed with a minimum 2mm thickness, utilizing high-quality paint materials and precise powder paint processing for durability.
7. Doors: Equipped with high-quality door locks and hinges, featuring disassemble doors that revolve 180° for easy maintenance access.
8. Noise Reduction: Employs a large-scale impedance combined type muffler, lined with top-quality soundproof and insulation materials, to achieve low noise levels.
9. Battery: Includes a high-quality maintenance-free battery, complete with connecting cables for reliable power supply.
10. Electrical Components: Fitted with standard MCB or MCCB, featuring renowned brand Delixi, with options available for Chint, ABB, and others.
11. Control Module: Comes standard with a Smartgen HGM6120N control module, equipped with AMF functionality. Optional upgrades include Deepsea, ComAp, Datakom, Deif, among others.
12. Additional Features: Incorporates a battery charger and an ATS connection port for added convenience.
13. Transportation Convenience: Includes four lift eyes, lift pockets on the base frame, and a lifting port on the canopy's top, ensuring easy and secure transportation.
Optional Additions:
1. Water-jacketed heater
2. Radiator water level sensor
3. Oil heater
4. Space heater
5. ATS and synchronization panels
6. Daily fuel tank
7. PMG (Permanent Magnet Generator) for the alternator
These optional features provide additional customization options to tailor the generator to specific requirements, ensuring versatility and adaptability across various applications.
Generator Set Specification | ||
Model | A-P33 | |
Max. Power | kVA | 33 |
kW | 26.4 | |
Rate Power | kVA | 30 |
kW | 24 | |
Frequency | Hz | 50 |
Rate Voltage | V | 400/230 |
Rate Current | A | 43.3 |
Fuel Tank Capacity | L | 60 |
Dimension For Open-type Genset | mm | 1460 X 750 X 1200 |
Weight For Open-type Genset | kg | 762 |
Dimension For Soundproof Genset | mm | 2050 X 900 X 1150 |
Weight For Soundproof Generator | kg | 1050 |
Noise Level for Soundproof Generator at 7M | dBA | 72 |
Battery for Starting | One of 80A Free Maintenance Battery |
Engine Specification | ||
Engine Manufacturer | Perkins | |
Engine Brand | Perkins | |
Engine Model | 1103A-33G | |
No. of Cylinder | 3 Cylinder in line | |
Aspiration | Naturally Aspirated | |
Governor | Electric | |
Engine Max. Output Power | kW | 31 |
Displacement | L | 3.3 |
Compression Ratio | 19.5 : 1 | |
Starting Voltage | V | 12 |
Bore | mm | 105 |
Stroke | mm | 127 |
Lubrication Oil Capacity | L | 7.8 |
Intake Air Flow | M3/Min | 2.16 |
Fuel Consumption at 100% Load | L/H | 7.1 |
Alternator Specification | ||
Alternator Manufacturer | Cummins Generator Technologies | |
Alternator Model | PI 144G | |
Alternator Brand | Stamford | |
Rate Output | kVA | 30 |
Frequency | Hz | 50Hz |
Altitude | M | ≤1000 |
Insulation | Class H | |
Phase | 3 Phase | |
Working Temperature without power decrease | ≤40℃ | |
Working Altitude without power decrease | ≤1000m | |
Automatic Voltage Regulation | SX460 | |
Protection Grade | IP23 | |
Alternator for optional | Leroy Somer, Marathon, Mecc Alte and Hosem Brushless alternator for optional | |
Q: Are Chinese generators reliable?
A: Yes! Chinese generators is good. With China's robust industrial infrastructure and expertise in manufacturing everything from smartphones to automobiles, the country has proven its ability to produce reliable and efficient products, including diesel generators.
That said, it's essential to do your due diligence when buying from China, as some generators may be designed for more budget-conscious markets. To ensure you're investing in a high-quality generator, check out my article below:
“Are Chinese Diesel Generators Reliable? How to Choose a Top-Quality Generator from China”
Q: How Do I Maintain a Perkins Diesel Generator?
A: Regular maintenance is crucial for ensuring the long lifespan and optimal performance of your Perkins diesel generator. Key tasks include changing the oil, replacing filters, and checking the overall system for wear and tear.
Perkins generators are known for their reliability, but like all machinery, they require consistent care to keep running smoothly. Proper maintenance not only extends the life of your generator but also ensures it operates efficiently when you need it most.
For a detailed maintenance schedule, check out our article on:
"Perkins Generator Maintenance Schedule"
Q: How to Import Generator Sets from China?
A: The process of importing a generator from China is simple and hassle-free. We can ship the goods directly to your designated seaport, and you only need to handle customs clearance and related procedures.
For more details, refer to my article:
"How to Import Generator Sets from China: A Comprehensive Guide for Businesses and Individuals."
Why Choose Hosem Power?
1. Hosem Power engaged in the generator area for 15 years, we have rich experience in R&D and manufacturing generator sets.
2. Every generator will be tested strictly before shipment, including:
1) Parts faults testing
2) Fuel tank pressure testing
3) Bolt tightening torque testing
4) Painting thickness testing
5) Voltage bearing and insulation testing
6) Noise testing
7) Loading Testing: 25%, 50%, 75%, 100%, 110% load to check verify that all control systems, alarm and shut-down protection.
3. production is submitted to ISO8528 and CE certification, and quality is certified by ISO9001 Management System to guarantee high-quality products and service.
FAQ
Q: What is a Perkins generator?
A: A Perkins generator refers to a generator set that is powered by a Perkins diesel engine. Perkins is a renowned manufacturer of reliable and efficient engines used in various industries, including power generation.
Q: What power output range is available for Perkins generators?
A: Perkins generators are available in a wide range of power outputs, from small portable units to large industrial generators. The power output can vary from a few kilovolt-amperes (KVA) to several megawatts (MW), depending on the specific model and application.
Q: What are the benefits of choosing a Perkins generator?
A: Perkins generators offer several benefits, including excellent fuel efficiency, reliable performance, low operating costs, and durability. Perkins engines are known for their robust construction, long service life, and ability to perform well even in harsh operating conditions.
Q: Are Perkins generators suitable for both standby and prime power applications?
A: Yes, Perkins generators are designed to serve both standby and prime power applications. Standby generators are used as backup power sources during utility outages, while prime power generators provide continuous power for extended periods.
Q: Can Perkins generators be used in various industries?
A: Yes, Perkins generators find applications in diverse industries such as construction, healthcare, telecommunications, manufacturing, agriculture, and more. They can power critical equipment, facilities, and processes in different sectors.
Q: Do Perkins generators comply with emission regulations?
A: Yes, Perkins engines used in generators comply with global emission regulations, such as those set by the Environmental Protection Agency (EPA) and the European Union (EU). They incorporate advanced technologies to reduce emissions and meet environmental standards.
Q: How often should Perkins generators undergo maintenance?
A: Regular maintenance is essential to ensure optimal performance and prolong the lifespan of Perkins generators. The maintenance intervals may vary based on factors such as operating hours, environmental conditions, and the specific model. It is recommended to follow the maintenance schedule outlined in the generator's user manual or consult with a qualified service provider.
Q: Can Perkins generators be synchronized and paralleled?
A: Yes, Perkins generators can be synchronized and paralleled to increase power output or achieve redundancy in larger installations. Synchronization and paralleling allow multiple generators to work together seamlessly, providing greater flexibility and reliability in power supply.
Q: Where can I get support and service for my Perkins generator?
A: Perkins has an extensive network of authorized service providers and distributors worldwide. They offer technical support, spare parts, and maintenance services for Perkins generators. You can contact your local Perkins dealer or visit their website for assistance.
Q: Are Perkins generators backed by warranty?
A: Yes, Perkins generators typically come with a manufacturer's warranty that covers the engine and generator components. The warranty duration may vary depending on the model and region. It is important to review the warranty terms and conditions provided by the manufacturer.
Model | Standby Power | Prime Power | Engine Model | Dimension | Weight | Datasheet | ||
kVA | kW | kVA | kW | LXWXH(MM) | KG | |||
A-P10-1 | 10 | 8 | 9 | 7 | 403A-11 G1 | 1950×800×1115 | 560 | Download |
A-P10-2 | 10 | 8 | 9 | 7 | 403D-11G | 1950×800×1115 | 560 | Download |
A-P14-1 | 14 | 11 | 13 | 10 | 403A-15G1 | 1950×800×1115 | 700 | Download |
A-P14-2 | 14 | 11 | 13 | 10 | 403D-15G | 1950×800×1215 | 700 | Download |
A-P15 | 16 | 13 | 15 | 12 | 403A-15G2 | 1950×800×1215 | 760 | Download |
A-P22-1 | 22 | 18 | 20 | 16 | 404A-22G1 | 2100×740×1115 | 740 | Download |
A-P22-2 | 22 | 18 | 20 | 16 | 404D-22G | 2100×740×1115 | 740 | Download |
A-P30 | 30 | 24 | 27 | 22 | 404D-22TG | 2300×980×1270 | 780 | Download |
A-P32 | 32 | 26 | 30 | 24 | 1103A-33G | 2300×980×1270 | 1250 | Download |
A-P50 | 50 | 40 | 45 | 36 | 1103A-33TG1 | 2600×1130×1540 | 1360 | Download |
A-P66 | 66 | 53 | 60 | 48 | 1103A-33TG2 | 2600×1130×1540 | 1580 | Download |
A-P72 | 72 | 57 | 65 | 52 | 1104A-44TG1 | 2800×1130×1560 | 1580 | Download |
A-P88-1 | 88 | 70 | 80 | 64 | 1104A-44TG2 | 2800×1130×1560 | 1580 | Download |
A-P88-2 | 88 | 70 | 80 | 64 | 1104C-44TAG1 | 2800×1130×1560 | 1600 | Download |
A-P110 | 110 | 88 | 100 | 80 | 1104C-44TAG2 | 2800×1130×1560 | 1720 | Download |
A-P150 | 150 | 120 | 135 | 108 | 1106A-70TG1 | 3200×1130×1715 | 2215 | Download |
A-P165 | 165 | 132 | 150 | 120 | 1106A-70TAG2 | 3600×1130×2105 | 2215 | Download |
A-P200 | 200 | 160 | 180 | 144 | 1106A-70TAG3 | 3600×1130×2105 | 2385 | Download |
A-P220 | 220 | 176 | 200 | 160 | 1106A-70TAG4 | 3600×1130×2105 | 2450 | Download |
A-P254 | 254 | 203 | 231 | 185 | 1506A-E88TAG2 | 4000×1422×2190 | 3485 | Download |
A-P283 | 283 | 226 | 257 | 206 | 1506A-E88TAG3 | 4000×1422×2190 | 3485 | Download |
A-P338 | 338 | 270 | 307 | 246 | 1506A-E88TAG5 | 4000×1422×2190 | 3625 | Download |
A-P400 | 400 | 320 | 350 | 280 | 2206C-E13TAG2 | 4400×1422×2450 | 4290 | Download |
A-P450 | 450 | 360 | 400 | 320 | 2206C-E13TAG3 | 4400×1422×2450 | 4290 | Download |
A-P500 | 500 | 400 | 455 | 364 | 2506C-E15TAG1 | 4600×1422×2530 | 5070 | Download |
A-P550 | 550 | 440 | 500 | 400 | 2506C-E 15TAG2 | 4600×1422×2530 | 5070 | Download |
A-P650 | 650 | 520 | 591 | 473 | 2806C-E 18TAG 1A | 4800×1822×2522 | 6000 | Download |
A-P700 | 700 | 560 | 650 | 520 | 2806A-E18TAG2 | 4800×1822×2522 | 6050 | Download |
A-P820 | 820 | 656 | 746 | 597 | 4006-23TAG2A | 6059×2438×2591 | 8250 | Download |
A-P880 | 880 | 704 | 800 | 640 | 4006-23TAG3A | 6059×2438×2591 | 8250 | Download |
A-P1000 | 1000 | 800 | 910 | 728 | 4008TAG1A | 6059×2438×2591 | 9820 | Download |
A-P1125-1 | 1125 | 900 | 1022 | 818 | 4008TAG2A | 6059×2438×2591 | 9820 | Download |
A-P1125-2 | 1125 | 900 | 1022 | 818 | 4008TAG2 | 6059×2438×2591 | 9820 | Download |
A-P1250 | 1250 | 1000 | 1125 | 900 | 4008-30TAG3 | 6059×2438×2591 | 9820 | Download |
A-P1375-1 | 1375 | 1100 | 1250 | 1000 | 4012-46TWG2A | 12192x2438x2896 | 12900 | Download |
A-P1375-2 | 1375 | 1100 | 1250 | 1000 | 4012-46TWG2 | 12192x2438x2896 | 12900 | Download |
A-P1500 | 1500 | 1200 | 1375 | 1100 | 4012-46TWG3A | 12192x2438x2896 | 13000 | Download |
A-P1650 | 1650 | 1320 | 1500 | 1200 | 4012-46TAG2A | 12192x2438x2896 | 13000 | Download |
A-P1850 | 1850 | 1480 | 1688 | 1350 | 4012-46TAG3A | 12192x2438x2896 | 13000 | Download |
A-P2000 | 2000 | 1600 | 1850 | 1480 | 4016TAG1A | 12192x2438x2896 | 16100 | Download |
A-P2200-1 | 2200 | 1760 | 2000 | 1600 | 4016TAG2A | 12192x2438x2896 | 16100 | Download |
A-P2200-2 | 2200 | 1760 | 2000 | 1600 | 4016-61TRG2 | 12192x2438x2896 | 16100 | Download |
A-P2500 | 2500 | 2000 | 2250 | 1800 | 4016-61TRG3 | 12192x2438x2896 | 16200 | Download |
Model | Standby Power | Prime Power | Engine Model | Dimension | Weight | Datasheet | ||
kVA | kW | kVA | kW | LXWXH(MM) | KG | |||
A-P13H | 13 | 10 | 11 | 9 | 403D-11G | 1950×800×1115 | 560 | Download |
A-P16H | 16 | 13 | 15 | 12 | 403D-15G | 1950×800×1215 | 700 | Download |
A-P19H | 19 | 15 | 17 | 14 | 403A-15G2 | 1950×800×1215 | 760 | Download |
A-P226H | 26 | 21 | 24 | 19 | 404D-22G | 2100×740×1115 | 740 | Download |
A-P35H | 35 | 29 | 33 | 26 | 404D-22TG | 2100×740×1115 | 740 | Download |
A-P38H | 38 | 30 | 35 | 28 | 1103A-33G | 2300×980×1270 | 1250 | Download |
A-P59H | 59 | 47 | 54 | 43 | 1103A-33TG1 | 2600×1130×1540 | 1360 | Download |
A-P75H | 75 | 60 | 68 | 55 | 1103A-33TG2 | 2600×1130×1540 | 1580 | Download |
A-P84H | 84 | 67 | 76 | 61 | 1104A-44TG1 | 2800×1130×1560 | 1580 | Download |
A-P100H-1 | 100 | 80 | 90 | 73 | 1104A-44TG2 | 2800×1130×1560 | 1580 | Download |
A-P100H-2 | 100 | 80 | 90 | 72 | 1104C-44TAG1 | 2800×1130×1560 | 1600 | Download |
A-P125H | 125 | 100 | 115 | 92 | 1104C-44TAG2 | 2800×1130×1560 | 1720 | Download |
A-P169H | 169 | 135 | 152 | 122 | 1106A-70TG1 | 3200×1130×1715 | 2215 | Download |
A-P188H | 188 | 150 | 169 | 135 | 1106A-70TAG2 | 3600×1130×2105 | 2215 | Download |
A-P219H | 219 | 175 | 197 | 158 | 1106A-70TAG3 | 3600×1130×2105 | 2385 | Download |
A-P273H | 273 | 218 | 248 | 198 | 1506A-E88TAG2 | 4000×1422×2190 | 3485 | Download |
A-P320H | 320 | 256 | 290 | 232 | 1506A-E88TAG3 | 4000×1422×2190 | 3485 | Download |
A-P390H | 390 | 312 | 352 | 282 | 1506A-E88TAG5 | 4000×1422×2190 | 3625 | Download |
A-P438H-1 | 438 | 350 | 400 | 320 | 2206C-E13TAG2 | 4400×1422×2450 | 4290 | Download |
A-P438H-2 | 438 | 350 | 400 | 320 | 2206C-E13TAG3 | 4400×1422×2450 | 4290 | Download |
A-P563H-1 | 563 | 450 | 500 | 400 | 2506C-E15TAG1 | 4600×1422×2530 | 5070 | Download |
A-P563H-2 | 563 | 450 | 500 | 400 | 2506C-E 15TAG2 | 4600×1422×2530 | 5070 | Download |
A-P687H-1 | 687 | 550 | 625 | 500 | 2806C-E 18TAG 1A | 4800×1822×2522 | 6000 | Download |
A-P687H-2 | 687 | 550 | 625 | 500 | 2806A-E18TAG2 | 4800×1822×2522 | 6000 | Download |
A-P825H | 825 | 660 | 750 | 600 | 4006-23TAG2A | 6059×2438×2591 | 8250 | Download |
A-P940H | 940 | 750 | 849 | 679 | 4006-23TAG3A | 6059×2438×2591 | 8250 | Download |
A-P1100H | 1100 | 880 | 1000 | 800 | 4008TAG2 | 6059×2438×2591 | 9820 | Download |
A-P1375H | 1375 | 1100 | 1250 | 1000 | 4012-46TWG2A | 12192x2438x2896 | 12900 | Download |
A-P1500H | 1500 | 1200 | 1375 | 1100 | 4012-46TWG3A | 12192x2438x2896 | 13000 | Download |
A-P1650H | 1650 | 1320 | 1500 | 1200 | 4012-46TAG2A | 12192x2438x2896 | 13000 | Download |
A-P1850H | 1850 | 1480 | 1690 | 1350 | 4012-46TAG3A | 12192x2438x2896 | 13000 | Download |
ATS
ATS cabinet is mainly applied to the automatic switch between prime and emergency power, composing an automatic emergency power supply system together with diesel generating sets. It will monitor prime power, When it is cut off, it can automatically switch loads such as emergency illumination, security power and fire fighting equipment to generating sets. Auto start, auto transfer, auto protection, auto power supply
Standard configuration:
Brand: ABB, Schneider, Socome, Suyang, AISIKAI
PARALLEL DISTRIBUTION CABINET
Parallel distribution cabinet is designed for the parallel running of main power diesel generator sets. The system can operate automatically or be controlled manually.
The system has the functions of automatic frequency detection, synchronizing detection and switch-on.
It is convenient to expand the capacity to satisfy the need of increasing load.
It can be used together with multiple generating sets (32 parallel generating sets max.) to control multiple diesel generating sets for automatic synchronization.
It offers stable frequency and voltage and can bear large-capacity load impact, achieving reliable supply, centralized management and more flexible power allocation.
Load Bank
The purpose of most land banks is used to test of the emergency generator sets, verifying all genset components are in optimal working condition under different loads. Another purpose is working combined with the generator set, to take the load of the generator set is always above 30%
Advantages of Load Bank
Three types of load banks are usually used to genset.