Powered by strong engine Cummins 4BTA3.9-G2, Mature engine technology, feature with very reliable performance
Global aftersale network. In the 3700 service location of Cummins, you can easily find it's professional service, as the most basic model, you can very easily find it's spare parts in the market
As our advantage product, our Cummins marine generator offer competitive price range and offer professional support
1 year and 1000 hours warranty
Item no.:
A-C63MPayment:
TT/LCPrice:
$7000Product origin:
ChinaColor:
BlackProduct weight:
750Lead Time:
30-35 days
The 50kW marine generator is designed to deliver reliable and consistent power for various marine applications. Powered by Cummins 4BTA3.9-G2 engine, it ensures smooth operation in demanding environments. Built with durable materials and advanced technology, the generator is suitable for fishing boat, commercial vessels, and offshore installations. Offering low maintenance, excellent performance, and quiet operation, the 50kW marine generator is an ideal choice for those seeking high-quality, continuous power on the water.
Engine Brand | Cummins |
Engine Model | 4BTA3.9-G2 Stroke, WaterCooled. |
Number of Cylinders | 4cylinders in Line |
Aspiration | Turbocharged and After-cooled |
Fuel system | PB pump |
Bore × Stroke | 102 x120 mm |
Rated Speed | 1800 RPM |
Compression ratio | 17.3:1 |
Displacement | 3.9L |
Prime Power | 65kW /87HP |
Speed Governor | GAC Electrical |
Cooling System | By heat exchanger |
Fuel Consumption |
17L@100% load 13L@75% load |
Starter Motor | DC24V |
Alternator Brand | Hosem |
Alternator Model | ASF 224E |
Frequency | 50Hz |
Voltage | 220V/400V 3 phase |
Prime Power | 50.4KW/63KVA |
Type | Brushless, Self-excited,marine type |
Power factor | 0.8 |
Insulation Grade | H |
Protection Grade | IP23(IP44 is optional) |
Phase / wire | 3 phase 3 wires |
AVR | MX460 |
Voltage regulation | ± 1.0 % |
Bearing | Single |
Winding leads | 12 |
Q: How Long Do 50kW Marine Diesel Generators Last?
A: With proper maintenance, Cummins marine diesel generators can last for thousands of hours, generally, the overhaul period is about 10,000 hours.
Q: What Maintenance is Required for Cummins Marine Diesel Generators?
A: Routine maintenance includes checking oil levels, replacing air filters, inspecting fuel systems, and ensuring proper cooling to maintain efficient operation.
Q: What is the Warranty for Cummins Marine Diesel Generators?
A: Cummins typically offers warranties on their marine generators, which may vary based on the model and region. It's recommended to consult the product documentation for specific warranty details.
Model | Standby Power | Prime Power | Engine Model | Dimension (Open Type) | Weight | Datasheet | ||
kVA | kW | kVA | kW | LXWXH(MM) | KG | |||
A-C25M | - | - | 25 | 20 | 4B3.9-G2 | 1410x700x1150 | 550 | Download |
A-C38M | - | - | 38 | 30 | 4BT3.9-G2 | 1410x700x1150 | 650 | Download |
A-C50M | - | - | 50 | 40 | 4BTA3.9-GM47 | 1670x850x1270 | 800 | Download |
A-C63M | - | - | 62.5 | 50 | 6BT5.9-GM83 | 1900x900x1300 | 1000 | Download |
A-C80M | - | - | 80 | 64 | 6BT5.9-GM83 | 1900x900x1300 | 1100 | Download |
A-C594M | - | - | 94 | 75 | 6BTA5.9-GM100 | 1900x900x1300 | 1250 | Download |
A-C113M | - | - | 113 | 90 | 6BTA5.9-GM100 | 2020x900x1300 | 1300 | Download |
A-C125M | - | - | 125 | 100 | 6CT8.3-GM115 | 2080x900x1360 | 1650 | Download |
A-C150M | - | - | 150 | 120 | 6CT8.3-GM115 | 2120x900x1360 | 1700 | Download |
A-C188M | - | - | 188 | 150 | 6CTA8.3-GM155 | 2220x1000x1790 | 1720 | Download |
A-C200M | - | - | 200 | 160 | 6LTAA8.9-GM200 | 2250x1000x1790 | 1750 | Download |
A-C250M | - | - | 250 | 200 | N855-DM | 2760x1000x1790 | 2700 | Download |
A-C313M | - | - | 313 | 250 | N855-DM | 2760x1000x1790 | 2800 | Download |
A-C350M | - | - | 350 | 280 | N855-DM | 2998x1000x1790 | 2950 | Download |
A-C375M | - | - | 375 | 300 | K19-DM | 2998x1000x1790 | 3360 | Download |
A-C438M | - | - | 438 | 350 | K19-DM | 3170x1000x1920 | 3480 | Download |
A-C500M | - | - | 500 | 400 | K19-DM | 3170x1000x1920 | 3650 | Download |
A-C850M | - | - | 850 | 680 | K38-DM | 4050x1500x2480 | 7200 | Download |
A-C1000M | - | - | 1000 | 800 | K38-DM | 4100x1500x2480 | 7350 | Download |
A-C1250M | 1250 | 1000 | K50-DM | 4500x1500x2480 | 9500 | Download |
Model | Standby Power | Prime Power | Engine Model | Dimension (Open Type) | Weight | Datasheet | ||
kVA | kW | kVA | kW | LXWXH(MM) | KG | |||
A-C31MH | - | - | 31 | 25 | 4B3.9-G2 | 1410x700x1150 | 550 | Download |
A-C44MH | - | - | 44 | 35 | 4BT3.9-G2 | 1410x700x1150 | 650 | Download |
A-C50MH | - | - | 50 | 40 | 4BTA3.9-GM65 | 1670x850x1270 | 700 | Download |
A-C63MH | - | - | 63 | 50 | 4BTA5.9-GM65 | 1760x900x1300 | 720 | Download |
A-C80MH | - | - | 80 | 64 | 6BT5.9-GM100 | 2020x900x1300 | 950 | Download |
A-C94MH | - | - | 94 | 75 | 6BT5.9-GM100 | 1980x900x1300 | 980 | Download |
A-C113MH | - | - | 113 | 90 | 6BTA5.9-GM120 | 1980x900x1300 | 1000 | Download |
A-C125MH | - | - | 125 | 100 | 6BTA5.9-GM120 | 2100x810x1360 | 1080 | Download |
A-C150MH | - | - | 150 | 120 | 6CTA8.3-GM175 | 2120x900x1360 | 1350 | Download |
A-C188MH | - | - | 188 | 150 | 6CTA8.3-GM175 | 2180x900x1360 | 1420 | Download |
A-C313MH | - | - | 313 | 250 | N855-DM | 2880x1000x1790 | 2560 | Download |
A-C350MH | - | - | 350 | 280 | N855-DM | 2880x1000x1790 | 2650 | Download |
A-C438MH | - | - | 438 | 350 | K19-DM | 3360x1000x1920 | 3350 | Download |
A-C500MH | - | - | 500 | 400 | K19-DM | 3360x1000x1920 | 3400 | Download |
A-C563MH | - | - | 563 | 450 | K19-DM | 3360x1000x1920 | 3520 | Download |
A-C875MH | - | - | 875 | 700 | K38-DM | 3760x1500x2480 | 6950 | Download |
A-C1000MH | - | - | 1000 | 800 | K38-DM | 3760x1500x2480 | 7100 | Download |
A-C1438MH | - | - | 1438 | 1150 | K50-DM | 4500x1500x2480 | 9200 | Download |
PARALLEL DISTRIBUTION CABINET
Parallel distribution cabinet is designed for the parallel running of main power diesel generator sets. The system can operate automatically or be controlled manually.
The system has the functions of automatic frequency detection, synchronizing detection and switch-on.
It is convenient to expand the capacity to satisfy the need of increasing load.
It can be used together with multiple generating sets (32 parallel generating sets max.) to control multiple diesel generating sets for automatic synchronization.
It offers stable frequency and voltage and can bear large-capacity load impact, achieving reliable supply, centralized management and more flexible power allocation.