Engaging in Generator More Than 15 Years
Search
  • How to save fuel consumption of genset Jun 23, 2022
    Fuel consumption is an important index to measure the performance of Genset, in our daily use, there are ways to reduce fuel consumption:   1.To make reasonable use of the Industrial generator set, it must first be used within the rated power range. Overloaded use will definitely increase the operating burden of the generator set and reduce the service life of the equipment. Unit damage, with the increase of the number of use, fuel consumption is bound to be higher   2. before the generator set is used, two layers of silk cloth can be added to the filter screen of the oil supply system to improve the combustion rate by reducing impurities in the oil, so as to reduce fuel consumption, or two layers of oil can be carried out first. Wait for four days to settle, then use   3. the generator set is usually cooled by air cooling and water cooling system during operation, but if the temperature is too low when starting, it will reduce the viscosity of oil and reduce the movemen...
  • Common Problems Analysis of Generator Sets Jul 20, 2022
    Due to the complex structure of the diesel generator set, many users buy the diesel generator set, but do not know how to operate it and maintain it, the following will introduce some precaution for ensuring good operation of Hosem Power diesel generator set:   What happens if the diesel generator is overloaded for a long time?   Genset usually cannot be overloaded when operating but can withstand short-term overloads. If the unit overload time is too long (exceed Overrated power) something can happen. Include: Overheating of cooling system Generator winding overheating Low oil pressure due to decomposition of lubricating oil concentration Unit life is shortened   What happens if the unit load is too low?   If the unit is operated at low load for a long time, the water temperature can not rise to the normal temperature, the viscosity of oil is large, and the friction becomes larger. The oil that should be burning in the cylinder is heated, causing paint to form on t...
  • The Necessity of Installing Protective Devices for Generator Sets Aug 12, 2022
    Although the diesel generator set is a relatively high-grade diesel generator set, but in the process of use often appear suddenly serious damage, so it is essential to install protective devices on the diesel generator set. Many users are reluctant to do this kind of protection because it saves money. In fact, protection measures are installed to protect diesel generator sets from excessive losses in unexpected situations. Hosem Power gives a few examples:   1, when the engine oil pipe burst and lack of oil, the oil pressure protection system starts to work, the diesel generator set immediately shut down.   2. When the engine oil supply system fails, the engine overspeed protection system starts to work, and immediately pull the oil breaker to stop the engine.   3. When the oil temperature and water temperature exceed the limit temperature, the temperature system starts to work, so that the engine stops.   When the diesel generator set engine occurs the above fault...
  • Notes on Using Diesel Generator Set Aug 12, 2022
      It is strictly prohibited to start diesel engine with load. Before starting the diesel generator set, note that the output air switch of the generator must be in the open state. After starting a normal diesel engine, it needs to run at idle speed for 3-5 minutes (about 700 RPM). The temperature in Winter is low, idle time should be appropriately extended to a few minutes. After the diesel engine starts, it is necessary to observe whether the oil pressure is normal, whether there is oil leakage, water leakage, and other abnormal phenomena.   If there is no abnormal phenomenon, increase the diesel engine speed to the rated speed of 1500 RPM. At this time, the generator display frequency is 50HZ, the voltage is 400V, and the output air switch can be closed and put into use. The diesel generator set is not allowed to run for a long time without load. (Because long-term no-load operation will make the diesel fuel injector can not be completely burned, resulting in carbon deposit...
  • Brand New 50kW Cummins Generators are Ready for Dispatch to Malaysia Oct 11, 2022
    Brand New 50kW Cummins Generators are Ready for Dispatch to Malaysia   CUMMINS is a leading global power equipment manufacturer. It devotes into design, manufacturing and distribution on the engines and related technologies including fuel systems, control systems, intake air treatment, filtration systems, exhaust gas treatment systems and power systems, and provides corresponding after-sales services. The displacement of CUMMINS products covers from 3.9 to 50 liters, and the power range is 24 to 1429KW.   Standard Features About 50kW Cummins Generator:   Excitation system: self-excited (AREP and PMG are optional)• ATS (automatic transfer switch) receptacle (optional)• Lockable battery isolator switch• Stainless galvanized zinc plates with strongcorrosion resistance (Optinal)• Vibration isolators between the engine/alternatorand base frame• Integrated wiring design• Base fuel tank for at least 8 hours running• Equipped with an industrial...
  • Diesel Generator for Australian Market, with 304 Stainless Steel Canopy and Double-wall Fuel Tank Jan 06, 2023
    Diesel Generator for Australian Market, with 304 Stainless Steel Canopy and Double-wall Fuel Tank   Generator Set Specification Model A-P165 Max. Power kVA 165 kW 132 Rate Power kVA 150 kW 120 Frequency Hz 50 Rate Voltage V 400/230 Rate Current A 216.5 Fuel Tank Capacity L 250 Dimension For Open-type Genset mm 2450 X 800 X 1400 Weight For Open-type Genset kg 1590 Dimension For Soundproof Genset mm 3200 X 1080 X 1500 Weight For Soundproof Generator kg 2090 Noise Level for Soundproof Generator at 7M dBA 72 Battery One of 120A Free Maintenance Battery   Engine Specification Engine Manufacturer Perkins Engines Company Limited Engine Brand Perkins Engine Model 1106A-70TAG2 No. of Cylinder 6 Cylinder in line Aspiration Turbocharged and Air to Air Aftercooled Governor Electric Engine Max. Output Power kW 153.6 Displacement L 7.0 Compression Ratio 16.0 : 1 Starting Voltage V 12 Bore mm 105 Stroke mm 135 Lubrication Oil Capacity L 16.5 Intake Air Flow L/S N.A. Fuel Consumption at 100%...
  • Generator Maintenance Check List Apr 10, 2023
    Regular inspection of the generator set is an indispensable item to ensure the long-term stable operation of the generator, Before using the engine, what items should we check the generator?    1. Check for any damage or wear to the generator, including any visible damage to the housing, wiring, or connections.   2. Check all fuel lines, fuel filters, and fuel tanks for any clogs, leaks, or damage.   3. Check the oil level and condition.   4. Inspect the spark plugs and wiring for any damage or wear.   5. Clean all parts of the generator, including the housing, fuel lines, and engine components.   6. Check the battery for any corrosion or damage.   7. Test the generator to ensure that it is working properly.   8. Inspect the alternator and other components of the generator system.   9. Adjust the generator settings as necessary.    
  • How to Buy An Generator for Your boat? Apr 11, 2023
    What is the difference between a marine generator and a generator?   The primary difference between a marine generator and a generator is their intended use. A marine generator is specifically designed to generate power for marine applications such as boats, ships, and other vessels. It is typically designed to withstand the harsh environment of being out on the open water, and is frequently more resistant to corrosion. A regular generator is designed to provide power for stationary applications, such as homes and businesses.   What benefits can I get from using a marine generator? Using a professional marine generator gives you access to a reliable source of power while on the open water. Marine generators are designed to provide consistent power even in rough seas or in areas with limited access to shore power. They are also designed to be corrosion-resistant and to withstand the harsh marine environment. Additionally, generators provide greater fuel efficiency, allowing yo...
  • Are Yangdong Engines Good? Apr 13, 2023
      Yangdong engines are manufactured by Yangdong Co., Ltd., a Chinese company that specializes in producing diesel engines and generators. While the quality and reliability of Yangdong engines can vary depending on the specific model and application, they are generally considered to be good quality and have a good reputation in the industry.   Yangdong has invested heavily in research and development and has developed engines that are known for their high performance and fuel efficiency. Many of their engines also meet international emission standards.   Yangdong engines are widely used in a variety of applications, including agricultural machinery, construction equipment, and power generation. The company has a strong commitment to customer service and provides a global network of authorized dealers and service providers to support customers with their engines.   Overall, while there may be some variation in the quality and reliability of Yangdong engines depending ...
  • Regular Cleaning Operation of Diesel Generator Filter May 06, 2023
      Regular cleaning of the filter of a diesel generator can help maintain the engine's efficiency and prolong its service life. The type of filter used in the diesel generator affects the cleaning process. There are three types of filters commonly used in Starlight diesel generators: felt filter, high pressure slot filter, and paper filter element type filter.   The felt filter is composed of a metal mesh, a silk cloth cover, and a felt filter piece. The filter element is installed in the filter body and is composed of several thicker and thinner pieces that are alternately installed on the filter screen. The fuel enters the inner cavity between the filter element and the housing from the fuel inlet pipe, and then flows into the inner cavity of the metal mesh through the felt filter and the silk cloth sleeve. The air is collected in the upper part of the filter, and the bleeder cock is used to release air from the oil chamber and filter the air in the fuel.   The high pre...
  • The Function and Adding Method of Coolant for Generator Set May 08, 2023
      What's the function of coolant of the diesel generator set?   The coolant, also known as antifreeze, plays a crucial role in maintaining the optimal operating temperature of a diesel generator set. Its primary function is to absorb the excess heat generated by the engine during operation and transfer it to the radiator, where it is dissipated into the atmosphere.   In addition to regulating the temperature, the coolant also prevents corrosion and rust formation in the engine's cooling system. It contains additives that inhibit the growth of algae, rust, and scale, thus prolonging the life of the engine components.   Moreover, the coolant also prevents the formation of ice during the winter months, which could damage the engine's cooling system. It also helps to maintain the engine's performance and efficiency by minimizing the risk of overheating, which can cause engine damage or failure.   How to check and fill radiator coolant in a diesel generator?   ...
  • Generator Radiator Maintenance and Rapair May 08, 2023
    What's the Ffunction of the Radiator of the Generator?   The function of the radiator on a diesel generator is to cool the engine by removing excess heat. During the combustion process, the engine produces a large amount of heat that must be dissipated to prevent the engine from overheating. The radiator is responsible for this process by circulating coolant through the engine and removing the excess heat. As the coolant flows through the engine, it absorbs the heat and transfers it to the radiator. The radiator then uses air flow to dissipate the heat from the coolant, cooling it down before recirculating it back into the engine. Without a functioning radiator, the engine would quickly overheat, causing severe damage and potentially leading to a catastrophic failure.     How to Do the Regular Maintenance for the Radiator?   Check the coolant level regularly: The coolant level should be checked at least once a week when the generator is in use. The coolant should be...
1 2
Whatever your needs, our equipment will ensure your business is always on.
Get a quote

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

skype

whatsapp