Hosem Power’s 500kW continuous-duty diesel generator is powered by the Cummins 12-cylinder KTA38-G2 engine, delivering high output and outstanding performance—especially for heavy-load applications such as large motors and mining equipment. Contact us today to get your China factory-direct price.
Item no.:
A-C825Payment:
TT/LCProduct weight:
7000
The 500kW generator powered by Cummins KTA38-G2 which is a 12-cylinder, high-output engine known for its exceptional durability. Its design is remarkably robust, featuring extremely heavy-duty materials—including a massive cast-iron cylinder block—engineered to withstand very high burst pressures and intense thermal loads. With proper maintenance, many units have been documented to operate for over 100,000 hours.
Powered by a Cummins 38L displacement engine, it delivers impressive torque and outstanding performance, especially during sudden load increases. This makes it an ideal choice for continuous power applications.
The K38 series engine has a long and proven history. It is widely used across industries such as global mining, marine vessels, major data centers, defense operations, and telecommunications base stations—consistently demonstrating its reliability and superior build quality over decades of operation.
| Engine Specification | ||
| Engine Manufacturer | Dongfeng Cummins Engine Co., Ltd. | |
| Engine Brand | Cummins | |
| Engine Model | KTA38-G2 | |
| No. of Cylinder | 12 Cylinder V Type | |
| Aspiration | Turbocharged & Aftercooled | |
| Governor | Electric | |
| Engine Max. Output Power | kW | 731 |
| Displacement | L | 37.8 |
| Compression Ratio | 14.5 : 1 | |
| Starting Voltage | V | 24 |
| Bore | mm | 159 |
| Stroke | mm | 159 |
| Lubrication Oil Capacity | L | 114 |
| Intake Air Flow | M3/Min | 55.2 |
| Fuel Consumption at 100% Load | L/H | 167 |
| Alternator Specification | ||
| Alternator Manufacturer | Hosem Power | |
| Alternator Model | ASF 354FS | |
| Alternator Brand | Hosem | |
| Rate Output | kVA | 800 |
| Frequency | Hz | 50Hz |
| Altitude | M | ≤1000 |
| Insulation | Class H | |
| Phase | 3 Phase | |
| Working Temperature without power decrease | ≤40℃ | |
| Working Altitude without power decrease | ≤1000m | |
| Automatic Voltage Regulation | SX440 | |
| Protection Grade | IP23 | |
| Alternator for optional | Leroy Somer, Marathon, Mecc Alte and Stamford Brushless alternator for optional | |

1. Is the 500kW generator suitable for continuous 24/7 operation?
Yes. Powered by the Cummins KTA38-G2 engine, this generator is built for continuous-duty operation, making it ideal for long-term, reliable power supply in industrial and commercial applications.
2. Besides Cummins, are there other engine options for the 500kW generator?
Yes. In addition to Cummins, we also offer other reputable engine brands for 500kW power output—such as Perkins, Weichai, and SDEC. Each brand has its own advantages and can meet different customer needs. For more details, please review the article below.
3. What are the drawbacks of this 500kW Cummins generator?
The Cummins KTA38-G2 engine does not meet modern emission standards such as Tier 3 or higher. Therefore, it may not be suitable for regions with strict emission regulations.
Additionally, compared to engines equipped with electronic fuel systems, this mechanical-injection Cummins model typically has slightly higher fuel consumption.
Contact us right now to get Chinese Factory Pricing
1. Hosem Power engaged in the generator area for 15 years, we have rich experience in R&D and manufacturing generator sets.
2. Every generator will be tested strictly before shipment, including:
1) Parts faults testing
2) Fuel tank pressure testing
3) Bolt tightening torque testing
4) Painting thickness testing
5) Voltage bearing and insulation testing
6) Noise testing
7) Loading Testing: 25%, 50%, 75%, 100%, 110% load to check verify that all control systems, alarm and shut-down protection.
3. production is submitted to ISO8528 and CE certification, and quality is certified by ISO9001 Management System to guarantee high-quality products and service.


| Model | Standby Power | Prime Power | Engine Model | Dimension Silent Type | Weight | Datasheet | ||
| kVA | kW | kVA | kW | LXWXH(MM) | KG | |||
| A-C22-1 | 22 | 18 | 20 | 16 | 4B3.9-G11 | 2300x 900x1250 | 765 | Download |
| A-C22-2 | 22 | 18 | 20 | 16 | 4B3.9-G2 | 2300x 900x1250 | 765 | Download |
| A-C28-1 | 28 | 22 | 25 | 20 | 4B3.9-G1 | 2300x 900x1250 | 765 | Download |
| A-C28-2 | 28 | 22 | 25 | 20 | 4B3.9-G2 | 2300x 900x1250 | 765 | Download |
| A-C44-1 | 44 | 35 | 40 | 32 | 4BT3.9-G1 | 2300x 900x1250 | 770 | Download |
| A-C44-2 | 44 | 35 | 40 | 32 | 4BT3.9-G2 | 2300x 900x1250 | 770 | Download |
| A-C55 | 55 | 44 | 50 | 40 | 4BT3.9-G2 | 2300x 900x1250 | 780 | Download |
| A-C60 | 60 | 50 | 55 | 45 | 4BTA3.9-G2 | 2450x900x1250 | 824 | Download |
| A-C72 | 72 | 57 | 65 | 52 | 4BTA3.9-G2 | 2450x900x1250 | 824 | Download |
| A-C88 | 88 | 70 | 80 | 63 | 4BTA3.9-G11 | 2450x900x1250 | 980 | Download |
| A-C100 | 100 | 77 | 90 | 70 | QSB3.9-G3 | 2450x900x1250 | 980 | Download |
| A-C110-1 | 110 | 88 | 100 | 80 | 6BT5.9-G1 | 2900×1080×1500 | 1150 | Download |
| A-C110-2 | 110 | 88 | 100 | 80 | 6BT5.9-G2 | 2900×1080×1500 | 1185 | Download |
| A-C121 | 121 | 96 | 110 | 87 | 6BT5.9-G2 | 2900×1080×1500 | 1185 | Download |
| A-C138 | 138 | 110 | 125 | 100 | 6BTA5.9-G2 | 2900×1080×1500 | 1280 | Download |
| A-C150-1 | 150 | 119 | 136 | 109 | QSB5.9-G3 | 3200×1080×1500 | 1350 | Download |
| A-C150-2 | 150 | 119 | 136 | 109 | 6BTAA5.9-G2 | 3200×1080×1500 | 1280 | Download |
| A-C175 | 175 | 140 | 160 | 127 | 6BTAA5.9-G12 | 3200×1080×1500 | 1300 | Download |
| A-C200-1 | 200 | 160 | 182 | 145 | 6CTA8.3-G1 | 3200×1080×1500 | 1600 | Download |
| A-C200-2 | 203 | 163 | 185 | 148 | 6CTA8.3-G2 | 3200×1080×1500 | 1550 | Download |
| A-C210 | 210 | 167 | 190 | 152 | QSB6.7-G4 | 3500×1126×1700 | 1550 | Download |
| A-C220 | 220 | 176 | 200 | 160 | 6CTAA8.3-G2 | 3500×1126×1700 | 1700 | Download |
| A-C275-1 | 275 | 220 | 250 | 200 | MTA11-G2A | 3900×1300×1900 | 2750 | Download |
| A-C275-2 | 275 | 220 | 250 | 200 | MTA11-G2 | 3900×1300×1900 | 2750 | Download |
| A-C275-3 | 275 | 220 | 250 | 200 | NTA855-G1 | 3900×1300×1900 | 3010 | Download |
| A-C275-4 | 275 | 220 | 250 | 200 | 6LTAA8.9-G2 | 3500×1126×1700 | 1900 | Download |
| A-C286 | 286 | 229 | 260 | 208 | 6LTAA8.9-G3 | 3500×1126×1700 | 2500 | Download |
| A-C290 | 290 | 232 | 260 | 208 | QSL8.9-G4 | 3500×1126×1700 | 1900 | Download |
| A-C300 | 300 | 240 | 275 | 220 | NTA855-G1A | 3900×1300×1900 | 3010 | Download |
| A-C300 | 300 | 240 | 273 | 218 | 6LTAA9.5-G3 | 3500×1126×1700 | 2500 | Download |
| A-C344-1 | 344 | 275 | 313 | 250 | MTAA11-G3 | 3900×1300×1900 | 2750 | Download |
| A-C350 | 350 | 280 | 313 | 250 | NTA855-G1B | 3900×1300×1900 | 2900 | Download |
| A-C344-3 | 344 | 275 | 313 | 250 | NTA855-G2 | 3900×1300×1900 | 2900 | Download |
| A-C344-4 | 344 | 275 | 313 | 250 | 6LTAA9.5-G1 | 3500×1126×1700 | 2750 | Download |
| A-C375 | 375 | 300 | 341 | 273 | NTA855-G2A | 3900×1300×1900 | 2950 | Download |
| A-C385 | 385 | 308 | 350 | 280 | NTA855-G4 | 3900×1300×1900 | 3000 | Download |
| A-C408 | 408 | 326 | 370 | 296 | QSZ13-G6 | 3420×1150×2190 | 3140 | Download |
| A-C413-1 | 413 | 330 | 375 | 300 | NTAA855-G7 | 3900×1300×1900 | 2800 | Download |
| A-C413-2 | 413 | 330 | 375 | 300 | KTA19-G2 | 3580×1277×2065 | 3950 | Download |
| A-C413-3 | 413 | 330 | 375 | 300 | 6ZTAA13-G3 | 4350×1450×2180 | 3220 | Download |
| A-C424 | 424 | 340 | 385 | 310 | 6ZTAA13-G3 | 4350×1450×2180 | 3220 | Download |
| A-C440 | 440 | 352 | 400 | 320 | 6ZTAA13-G3 | 4350×1450×2180 | 3220 | Download |
| A-C450 | 450 | 360 | N/A | N/A | NTAA855-G7A | 3000×1050×1780 | 2900 | Download |
| A-C456 | 456 | 365 | 415 | 332 | QSZ13-G7 | 3420×1150×2190 | 3140 | Download |
| A-C484 | 484 | 387 | 440 | 352 | 6ZTAA13-G2 | 4350×1450×2180 | 3220 | Download |
| A-C495-1 | 495 | 396 | 450 | 360 | KTA19-G3 | 4700×1800×2380 | 2900 | Download |
| A-C495-2 | 495 | 396 | 450 | 360 | 6ZTAA13-G4 | 4350×1450×2180 | 3220 | Download |
| A-C495-3 | 495 | 396 | 450 | 360 | QSZ13-G2 | 4700×1800×2380 | 3220 | Download |
| A-C511 | 511 | 409 | 465 | 372 | QSZ13-G5 | 4700×1800×2380 | 3220 | Download |
| A-C550-1 | 550 | 440 | 500 | 400 | KTA19-G3A | 4700×1800×2380 | 4250 | Download |
| A-C550-2 | 550 | 440 | 500 | 400 | KTA19-G4 | 4700×1800×2380 | 4300 | Download |
| A-C560 | 560 | 448 | 510 | 408 | QSZ13-G3 | 4700×1800×2380 | 3220 | Download |
| A-C575 | 575 | 462 | 525 | 420 | KTAA19-G5 | 4700×1800×2380 | 4550 | Download |
| A-C633 | 633 | 506 | 575 | 460 | KTAA19-G6 | 4700×1800×2380 | 4550 | Download |
| A-C650 | 650 | 520 | N/A | N/A | KTA19-G8 | 4700×1800×2380 | 4550 | Download |
| A-C688-1 | 688 | 550 | N/A | N/A | KTAA19-G6A | 4700×1800×2380 | 4700 | Download |
| A-C688-2 | 687 | 550 | 625 | 500 | KT38-G | 6050×2438×2591 | 6000 | Download |
| A-C784 | 784 | 627 | 713 | 570 | KTA38-G1 | 6050×2438×2591 | 6150 | Download |
| A-C800 | 800 | 640 | 725 | 580 | KT38-GA | 6050×2438×2591 | 6400 | Download |
| A-C825 | 825 | 660 | 750 | 600 | KTA38-G2 | 6050×2438×2591 | 6600 | Download |
| A-C880 | 880 | 704 | 800 | 640 | KTA38-G2B | 6050×2438×2591 | 6700 | Download |
| A-C1000 | 1000 | 800 | 910 | 728 | KTA38-G2A | 6050×2438×2591 | 6850 | Download |
| A-C1100 | 1100 | 880 | 1000 | 800 | KTA38-G5 | 6050×2438×2591 | 7150 | Download |
| A-C1250 | 1250 | 1000 | N/A | N/A | KTA38-G9 | 6050×2438×2591 | 7250 | Download |
| A-C1375 | 1375 | 1100 | 1250 | 1000 | KTA50-G3 | 12192×2438×2591 | 9140 | Download |
| A-C1513 | 1513 | 1210 | 1375 | 1100 | KTA50-G8 | 12192×2438×2591 | 9400 | Download |
| A-C1650 | 1650 | 1320 | 1500 | 1200 | KTA50-GS8 | 12192×2438×2591 | 9600 | Download |
| Model | Standby Power | Prime Power | Engine Model | Dimension (Silent Type) | Weight | Datasheet | ||
| kVA | kW | kVA | kW | LXWXH(MM) | KG | |||
| A-C28H | 28 | 22 | 25 | 20 | 4B3.9-G11 | 2300x 900x1250 | 765 | Download |
| A-C35H | 35 | 28 | 32 | 26 | 4B3.9-G2 | 2300x 900x1250 | 765 | Download |
| A-C40H | 40 | 32 | 36 | 29 | 4BT3.9-G12 | 2300x 900x1250 | 770 | Download |
| A-C50H | 50 | 40 | 45 | 36 | 4BT3.9-G2 | 2300x 900x1250 | 790 | Download |
| A-C60H | 60 | 48 | 55 | 44 | 4BTA3.9-G2 | 2300x 900x1250 | 824 | Download |
| A-C75H | 75 | 60 | 68 | 55 | 4BTA3.9-G2 | 2300x 900x1250 | 824 | Download |
| A-C100H | 100 | 80 | 90 | 72 | 4BTA3.9-G11 | 2300x 900x1250 | 980 | Download |
| A-C125H | 125 | 100 | 114 | 91 | 6BT5.9-G2 | 2900×1080×1500 | 1185 | Download |
| A-C150H | 150 | 120 | 136 | 109 | 6BTA5.9-G2 | 2900×1080×1500 | 1185 | Download |
| A-C165H | 165 | 132 | 150 | 120 | 6BTAA5.9-G2 | 3200×1080×1500 | 1185 | Download |
| A-C188H | 188 | 150 | 170 | 136 | 6BTAA5.9-G12 | 3200×1080×1500 | 1300 | Download |
| A-C220H | 220 | 200 | 200 | 160 | 6CTA8.3-G2 | 3200×1080×1500 | 1550 | Download |
| A-C250H | 250 | 200 | 227 | 182 | 6CTAA8.3-G2 | 3500×1140×1700 | 1700 | Download |
| A-C275H | 275 | 220 | N/A | N/A | NT855-GA | 3900×1300×1900 | 2800 | Download |
| A-C300H | 300 | 240 | 273 | 218 | 6LTAA8.9-G2 | 3500×1140×1700 | 2200 | Download |
| A-C344H | 344 | 275 | 313 | 250 | NTA855-G1 | 3900×1300×1900 | 2900 | Download |
| A-C316H | 316 | 253 | 288 | 230 | 6LTAA8.9-G3 | 3500×1140×1700 | 2250 | Download |
| A-C330H | 330 | 264 | 300 | 240 | 6LTAA9.5-G3 | 3500×1126×1700 | 2500 | Download |
| A-C375H | 375 | 300 | 344 | 275 | NTA855-G1B | 3900×1300×1900 | 2950 | Download |
| A-C375H-1 | 375 | 300 | 344 | 275 | NTA855-G2 | 3900×1300×1900 | 2950 | Download |
| A-C347H | 347 | 277 | 315 | 252 | 6LTAA9.5-G1 | 3500×1126×1700 | 2640 | Download |
| A-C438H | 438 | 350 | 398 | 318 | NTA855-G3 | 3900×1300×1900 | 2950 | Download |
| A-C424H | 424 | 339 | 386 | 309 | 6ZTAA13-G3 | 3500×1126×1700 | 3220 | Download |
| A-C445H | 445 | 356 | 405 | 324 | QSZ13-G6 | 4700×1800×2380 | 3140 | Download |
| A-C500H | 500 | 400 | 455 | 364 | KTA19-G2 | 4700×1800×2380 | 2900 | Download |
| A-C480H | 480 | 384 | 436 | 349 | 6ZTAA13-G2 | 3500×1126×1700 | 3220 | Download |
| A-C500H | 500 | 400 | 455 | 364 | 6ZTAA13-G4 | 3500×1126×1700 | 3220 | Download |
| A-C500H-1 | 500 | 400 | 455 | 364 | QSZ13-G2 | 4700×1800×2380 | 3220 | Download |
| A-C511H | 511 | 409 | 465 | 372 | QSZ13-G7 | 4700×1800×2380 | 3220 | Download |
| A-C560H | 560 | 448 | 509 | 407 | KTA19-G3 | 4700×1800×2380 | 2900 | Download |
| A-C550H | 550 | 440 | 500 | 400 | QSZ13-G5 | 4700×1800×2380 | 3220 | Download |
| A-C530H | 530 | 424 | 482 | 386 | QSZ13-G3 | 4700×1800×2380 | 3220 | Download |
| A-C625H | 625 | 500 | 568 | 455 | KTA19-G3A | 4700×1800×2380 | 4250 | Download |
| A-C625H-1 | 625 | 500 | 568 | 455 | KTA19-G4 | 4700×1800×2380 | 4300 | Download |
| A-C660H | 660 | 528 | 600 | 480 | KTAA19-G5 | 4700×1800×2380 | 4550 | Download |
| A-C750H | 750 | 600 | N/A | N/A | KTAA19-G6A | 4700×1800×2380 | 4550 | Download |
| A-C850H | 850 | 680 | 775 | 620 | KT38-G | 6050×2438×2591 | 6000 | Download |
| A-C963H | 963 | 770 | 875 | 700 | KTA38-G1 | 6050×2438×2591 | 6150 | Download |
| A-C1000H | 1000 | 800 | 909 | 727 | KTA38-G2 | 6050×2438×2591 | 6600 | Download |
| A-C1031H | 1031 | 825 | 938 | 750 | KTA38-G2B | 6050×2438×2591 | 6700 | Download |
| A-C1100H | 1100 | 880 | 1000 | 800 | KTA38-G2A | 6050×2438×2591 | 6850 | Download |
| A-C1250H | 1250 | 1000 | 1136 | 909 | KTA38-G4 | 6050×2438×2591 | 7150 | Download |
| A-C1525H | 1525 | 1220 | N/A | N/A | KTA38-G9 | 6050×2438×2591 | 7250 | Download |
| A-C1513H | 1513 | 1210 | 1375 | 1100 | KTA50-G3 | 12192×2438×2591 | 9140 | Download |
| A-C1733H | 1733 | 1386 | 1575 | 1260 | KTA50-G9 | 12192×2438×2591 | 9400 | Download |
ATS
ATS cabinet is mainly applied to the automatic switch between prime and emergency power, composing an automatic emergency power supply system together with diesel generating sets. It will monitor prime power, When it is cut off, it can automatically switch loads such as emergency illumination, security power and fire fighting equipment to generating sets. Auto start, auto transfer, auto protection, auto power supply
Standard configuration:
Brand: ABB, Schneider, Socome, Suyang, AISIKAI

PARALLEL DISTRIBUTION CABINET
Parallel distribution cabinet is designed for the parallel running of main power diesel generator sets. The system can operate automatically or be controlled manually.
The system has the functions of automatic frequency detection, synchronizing detection and switch-on.
It is convenient to expand the capacity to satisfy the need of increasing load.
It can be used together with multiple generating sets (32 parallel generating sets max.) to control multiple diesel generating sets for automatic synchronization.
It offers stable frequency and voltage and can bear large-capacity load impact, achieving reliable supply, centralized management and more flexible power allocation.

Load Bank
The purpose of most land banks is used to test of the emergency generator sets, verifying all genset components are in optimal working condition under different loads. Another purpose is working combined with the generator set, to take the load of the generator set is always above 30%
Advantages of Load Bank
Four types of load banks are usually used to genset.